• Description

Product Description

65 MM AND 150 MM Variable Area Flow Meters

(1) Variable Area Flow Meter Types select from:36 for 65 mm flowtube aluminum frame 37 for 65 mm flowtube 316 SS frame 38 for 150 mm flowtube aluminum frame 39 for 150 mm flowtube 316 SS frame (2) Flow Tube and Float by Range select from:07G for 65 mm 5.77 cc/mi air 0.07 cc/min water 07ST for 65 mm 16.77 cc/mi air 0.28 cc/min water 07C for 65 mm 32.99 cc/mi air 0.62 cc/min water

65 MM AND 150 MM Variable Area Flow Meters

Option Descriptions:(1) Variable Area Flow Meter Types select from:36 for 65 mm flowtube aluminum frame. 37 for 65 mm flowtube 316 SS frame. 38 for 150 mm flowtube aluminum frame. 39 for 150 mm flowtube 316 SS frame. (2) Flow Tube and Float by Range select from:07G for 65 mm 5.77 cc/mi air 0.07 cc/min water. Corel Ventura - MANUALvariable area principle to indicate the flow rate of a liquid or a gas. The basic meter components, as shown in Figure 1, are a tapered glass tube, a float, and a metal body. A scale is provided on the glass metering tube. The float is guided by flutes formed on the inside surface of the tube; the height of the

FLOW METER Suppliers and Manufacturers

Flowmeter Supplier Singapore. Nov 23, 2016 8174. Flow Meters , Flow Switches and More Flowmeters.sg is a flow meter website with a focus on meeting local needs on the island. We carry all types of flowmeters for gas, liquids and steam. Choose from a range of coriolis, magnetic, turbine, vortex, piston, gear or ultrasonic flow measurement Flow Meters InstrumartHighly accurate and reliable turbine flow meters offer an ideal solution for standard clean filtered liquid flow applications. Starting at $1,201.00. Badger Meter VN2000 Vortex Flow Meter. Measures the volumetric flow, mass flow rate, or BTU/energy of steam, gas, or

Flowmeter Supplier Singapore Coriolis Flowmeter, Air and

Variable area flow meter Model VLFH is a sturdy industrial flow meter with DN or ANSI flange connections. It is a reliable instrument for measuring and monitoring liquid and gas flows. Typical applications are sealing and cooling water, lubrication oil and flush water measurements View All Gas Flow Meters & Mass Controllers Sierra InstrumentsGas Flow Meters & Mass Controllers Accurate Mass Flow Measurement. Sierra designs and manufactures a wide range of today's most advanced analog and digital gas flow meters, mass flow meters, mass controllers and switches across three core technologies:Capillary Thermal, Immersible Thermal, and Mass Vortex.Each gas flowmeter or gas controller meets exacting standards, and we

How does a variable area flow meter work? Omega

The variable area flow meter's operation is based on the variable area principle:fluid flow raises a float in a tapered tube, increasing the area for passage of the fluid. The greater the flow, the higher the float is raised. The height of the float is directly proportional to the flowrate. With liquids as water, the float is raised by a combination of the buoyancy of the liquid and the velocity head of the fluid. How does a variable area flow meter work? Omega a glass-tube variable area flow meter should be installed at eye level. The scale can be calibrated for direct reading of air or water, or can read percentage of range. In general, glass tube variable area flow meters can measure flows up to about 60 gpm water and 200 scfh air.

In-line flow meter, In-line flowmeter - All industrial

thermal mass flow meter. IN-FLOW® Select series. Process pressure:100, 64, 200, 400 bar. Volumetric flow rate:183.3 l/min. Weatherproof (IP65) and Rugged Design IN-FLOW Series Mass Flow Meters/Controllers are thermal, bypass-type, mass flow meters of modular construction with a 'industrial style' pc-board housing. PTFE Variable Area Flow Meters with ValvesThe FL-3000 and FL-3100 Series variable area flow meters with built in valve are designed for applications which involve corrosive or ultra-pure fluids. The meters are equipped with built-in PTFE needle valves with PCTFE, borosilicate glass, sapphire, and Perfluoroelastomer O-rings.

PTFE Variable Area Flow Meters with Valves

Variable Area Flow Meter, with range of 28,326 cc/min air, 798 cc/min water. 150 mm Variable Area Flow Meter with valve Models. FL-3145SA. £ 279.00. Availability:4 weeks. Qty. Variable Area Flow Meter, with range of 37 cc/min air, 0.56 cc/min water, ±5% FS accuracy. Product Categories Dwyer InstrumentsVariable Area Tapered bore in-line indicators for flow rate. Ideal for high purity or corrosive liquid applications, gas and liquid applications, air samplers and medical applications. Flowmeters are shipped assembled and ready for panel mounting. Variable Area Selection Guide

Rotameter- Working Principle, Uses, Pros, Cons, and Handling

Oct 01, 2020 · Since there is variation in the cross-sectional area of the tube, it is known as a variable area flowmeter. Inside the tube consists of a metering float. The glass tube consists of readings built in it. When there is no flow of fluid through the rotameter, the float lies at the base of the tube. When the fluid flows to the tube through the base RotametersVariable Area Flow Meters Tech Info from Cole Oct 15, 2018 · The Variable-Area type flowmeter, or Rotameter, is one of the most economical and reliable of flow measurement instruments. In various configurations flow meters can be designed to withstand high pressures, corrosive fluids, high temperatures, and is completely independent of factors influencing electronic meters.

Selecting the Right FlowmeterPart 1 - Cole-Parmer

Design overview:The variable-area flowmeter (Figure 1) is one of the oldest technologies available and arguably the most well-known. It is constructed of a tapered tube (usually plastic or glass) and a metal or glass float. The volumetric flowrate through the tapered tube Types of Flow Meters and their Applications What Is Piping

  • Differential head type flowmetersTypes of Orifice plates (Fig. 1) Concentric orifice plate:Most commonly used. Segmental & Eccentric orifice plate:Figure showing Venturi meter and Annubar FlowmeterFeatures of Venturimeters. Design Pressure:No limitation. Limited by DP transmitter/ pipe press.ratings.Variable area flowmetersDesign Features of Rotameters. Design Pressure:Upto 350 PSIG (GLASS TUBE) / 720 PSIG (METAL TUBE). Design Temperature:See full list on whatispipingInline Flowmeters McMaster-CarrRated for at least six times the pressure of standard flowmeters for air, these can withstand pressures of at least 600 psi. Easy-Read High-Pressure Quick-Clean Flow Sights for Water. Determine the flow rate and total flow volume of water with the same meter. Washdown

    Variable Area Flow Meters (Rotameters) - Brooks Instrument

    Process-proven flow meters. For maximum repeatability and reliability. As one of the pioneering manufacturers in variable area (VA) flow meter (rotameter) technology, Brooks Instrument has created a diverse and proven portfolio of gas flow meters, installed and in use across virtually every industry. From inline to low volume flow meters Brooks offers high-performance gas and water flow measurement Variable Area Flow Meters for Corrosive Applications These special flowmeters utilize PVDF and glass wetted parts for excellent corrosion resistance where standard variable area flow meters would be unacceptable. Because of this construction, these flowmeters can be used with most acids and bases, in addition to working with many organic solvents.

    WALLACE & TIERNAN VAREA-METER FLOW

    These glass-tube purgemeters have a one-piece molded Kynar® frame and end fittings for long life in highly corrosive atmospheres. An optional Kynar® flow control valve is available. Scales are 3 inches long. Write for Catalog File 510.105. These glass-tube meters have a rugged stainless steel frame, available in 1 1/2-inch and 3-inch scale lengths. Water Rotameter For Sale Solenoid Valve Manufacturer LZB-40F-Anti-corrosion Glass Tube Rotameter. LZB-FA100-Glass Tube Rotameter. LZM-15Z-Series Acrylic Panel water air flowmeter . LZM-15G- Plastic Water Flow meter . The Water Rotameter is a form of variable area flow meter that has a simple operation whereby a l Jun.02 2021.

    Variable Area Flow meters - OMEGA

    Apr 17, 2019 · The most common size is a glass tube variable area flow meter with -in (6 mm) connections, a range of 0.05-0.5 gpm (0.2-2.0 lpm) on water or 0.2-2.0 scfm (0.3-3.0 cmph) in air service. Typical accuracy is ±5% FS over a 10:1 range, and the most